Procedural outcomes associated with use of the AngioVac System for right heart thrombi: A safety report from RAPID registry data

Author:

Moriarty John M1ORCID,Liao Millie2ORCID,Kim Grace Hyun J34,Yang Eric4ORCID,Desai Kush5,Ranade Mona1,Plotnik Adam N1

Affiliation:

1. Department of Radiology, Division of Interventional Radiology, David Geffen School of Medicine at UCLA, Los Angeles, CA, USA

2. Loma Linda University School of Medicine, Loma Linda, CA, USA

3. Department of Radiological Sciences, David Geffen School of Medicine at UCLA, Los Angeles, CA, USA

4. Department of Medicine, Division of Cardiology, UCLA Medical Center, Los Angeles, CA, USA

5. Department of Radiology, Division of Interventional Radiology, Feinberg School of Medicine, Northwestern University, Chicago, IL, USA

Abstract

Background: Right heart thrombi can be a source of considerable morbidity and mortality, especially when associated with pulmonary embolism. Methods: To understand the safety and procedural efficacy associated with vacuum-assisted thrombectomy using the AngioVac System (AngioDynamics, Latham, NY, USA) to remove right heart thrombi, we conducted a subanalysis of the Registry of AngioVac Procedures in Detail (RAPID) multicenter registry representing 47 (20.1%) of 234 participants in the registry. Forty-two (89.4%) patients had thrombi located in the right atrium alone, three (6.4%) in the right ventricle alone, and two (4.3%) in both the right atrium and ventricle. Four (8.5%) patients had concomitant caval thrombi, three (6.4%) also had catheter-related thrombi, and one (2.1%) patient had both caval and catheter-related thrombi with their right heart thrombi. Results: Extracorporeal bypass time was less than 1 hour for 39 (83.0%) procedures. Seventy to 100% removal of thrombus was achieved in 59.6% of patients. Estimated blood loss was less than 250 cc for 43 procedures (91.6%). Mean hemoglobin decreased from 10.7 ± 2.2 g/dL preoperatively to 9.6 ± 1.6 g/dL postoperatively. Transfusions were administered for eight procedures (17.0%), with only one (2.1%) patient receiving more than 2 units of blood. Six patients (12.8%) experienced procedure-related adverse events, including three (6.4%) patients who experienced distal emboli and three (6.4%) patients who developed bleeding-related complications. All adverse events resolved prior to discharge. There was one death (2.1%) reported that was not procedure related. Conclusion: Vacuum-assisted thrombectomy can be performed safely in patients with right heart thrombi. ClinicalTrials.gov Identifier: NCT04414332.

Publisher

SAGE Publications

Subject

Cardiology and Cardiovascular Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3