Near-infrared spectroscopy monitoring during endovascular treatment for acute ischaemic stroke

Author:

Collette Sabine L1ORCID,Venema Allart M2,Eleveld Nick3,Absalom Anthony R2,Scheeren Thomas WL2,Verhoeve Simon2,de Groot Jan Cees1,Elting Jan Willem J3,Uyttenboogaart Maarten13,Bokkers Reinoud PH1,Sahinovic Marko M2

Affiliation:

1. Department of Radiology, Medical Imaging Centre, University Medical Centre Groningen, University of Groningen, Groningen, The Netherlands

2. Department of Anaesthesiology, University Medical Centre Groningen, University of Groningen, Groningen, The Netherlands

3. Department of Neurology, University Medical Centre Groningen, University of Groningen, Groningen, The Netherlands

Abstract

Introduction: The aim of endovascular treatment (EVT) for acute ischaemic stroke is to relieve the cerebral tissue hypoxia in the area supplied by the occluded artery. Near-infrared spectroscopy (NIRS) monitoring is developed to assess regional cerebral tissue oxygen haemoglobin saturation (rSO2). We aimed to investigate whether NIRS can detect inter- and intra-hemispheric rSO2 differences during EVT. Patients and methods: In this prospective, observational study, patients undergoing EVT for a proximal intracranial occlusion of the anterior circulation between May 2019 and November 2020, were included. A four-wavelength NIRS monitor (O3® Regional Oximeter (Masimo, Irvine, CA)) was used to measure rSO2 during EVT with sensors placed over the temporal lobes in 20 patients and over the frontal lobes in 13 patients. The Wilcoxon signed-rank test was used to test for inter-hemispheric rSO2 differences after groin puncture and after recanalisation, and intra-hemispheric rSO2 changes before and after recanalisation. Results: In the temporal cohort, no inter-hemispheric rSO2 differences were observed after groin puncture (median [IQR] rSO2 affected hemisphere, 70% [67–73] and unaffected hemisphere, 70% [66–72]; p = 0.79) and after recanalisation. There were no intra-hemispheric rSO2 changes over time. In the frontal cohort, no inter- and intra-hemispheric rSO2 differences or changes were found. Discussion and conclusion: A NIRS monitor could not detect inter- and intra-hemispheric rSO2 differences or changes during EVT, irrespective of the sensor position. It is likely that even with temporal sensor application, a significant proportion of the received NIRS signal was influenced by oxygenation of surrounding tissues.

Publisher

SAGE Publications

Subject

Cardiology and Cardiovascular Medicine,Neurology (clinical)

Cited by 6 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3