Vibrant Soundbridge Implantable Hearing Device: Critical Review and Single-Surgeon Short- and Long-Term Results

Author:

Luetje Charles M.1,Brown Sandra A.1,Cullen Robert D.1

Affiliation:

1. From the Otologic Center, Kansas City, Mo.

Abstract

We conducted a retrospective descriptive study of a series of 31 consecutively presenting patients who had been implanted with the Vibrant Soundbridge middle ear hearing device. All implantations had been performed by the senior author. Three of these patients had undergone bilateral implantation, and 4 others had undergone subsequent explantation and reimplantation in response to known or suspected device failure, giving us a total of 34 ears and 38 implants. Our goal was to ascertain short- and long-term outcomes as measured by conventional audiometry (pure-tone average at 1 to 6 kHz) and long-term benefit as defined by the use or nonuse of the device. We found that at the initial activation session 2 months postoperatively, the average hearing thresholds were within 3 dB of the preoperative thresholds in all 34 ears and all 38 implants. The mean short-term gain at activation in the 38 implants was 28.1 dB. Nineteen patients (20 ears) were available for long-term evaluation, with the length of follow-up ranging from less than 1 year to 11 years (mean: 7.3). Of these 20 ears, 9 demonstrated further gain (mean: 10.8 dB) despite any natural hearing deterioration; of the remaining 11 ears, gain was unchanged in 2, diminished in 7 (mean: −3.6 dB), and gain data were unavailable in 2. In the final analysis, there were 20 user ears and 10 nonuser ears; 4 ears were lost to all follow-up. We conclude that direct-drive hearing with the Vibrant Soundbridge middle ear hearing device is beneficial and provides sustained audiometric gain. Factors that have a significant impact on patient use or nonuse include difficulty in obtaining audiologic support and the direct and indirect costs of the device. Without audiologic or financial support, some patients may choose to become nonusers and to either switch to conventional hearing aid amplification or become apathetic about hearing improvement.

Publisher

SAGE Publications

Subject

Otorhinolaryngology

Cited by 7 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3