Instrumental dead space and proximal working channel connector design in flexible ureteroscopy: a new concept

Author:

Kwok Jia-Lun12ORCID,De Coninck Vincent345,Pietropaolo Amelia64ORCID,Juliebø-Jones Patrick74ORCID,Ventimiglia Eugenio845,Tailly Thomas94,Alexander Schmid Florian1,Hunziker Manuela1,Poyet Cédric1,Traxer Olivier105,Eberli Daniel1,Keller Etienne Xavier1145

Affiliation:

1. Department of Urology, University Hospital Zurich, University of Zurich, Zurich, Switzerland

2. Department of Urology, Tan Tock Seng Hospital, Singapore

3. Department of Urology, AZ Klina, Brasschaat, Belgium

4. Endourology & Urolithiasis Working Group, Young Academic Urologists (YAU), Arnhem, The Netherlands

5. Progressive Endourological Association for Research and Leading Solutions (PEARLS), Paris, France

6. Department of Urology, University Hospital Southampton, Southampton, UK

7. Department of Urology, Haukeland University Hospital, Bergen, Norway

8. Division of Experimental Oncology/Unit of Urology, Urological Research Institute, IRCCS Ospedale San Raffaele, Milan, Italy

9. Department of Urology, University Hospital Ghent, Ghent, Belgium

10. Sorbonne Université, GRC n°20, Groupe de Recherche Clinique sur la Lithiase Urinaire, Hôpital Tenon, F-75020, Paris, France

11. Department of Urology, University Hospital Zurich, University of Zurich, Frauenklinikstrasse 10, CH-8091 Zurich, Switzerland

Abstract

Objective:The objective of this study was to evaluate a new concept in flexible ureteroscopy: instrumental dead space (IDS). For this purpose, various proximal working channel connector designs, as well as the impact of ancillary devices occupying the working channel were evaluated in currently available flexible ureteroscopes.Design and methods:IDS was defined as the volume of saline irrigation needed to inject at the proximal connector for delivery at the distal working channel tip. Because IDS is related to working channel diameter and length, proximal connector design, as well as occupation of working channel by ancillary devices, these parameters were also reviewed.Results:IDS significantly varied between flexible ureteroscope models, ranging from 1.1 ml for the Pusen bare scopes, to 2.3 ml for Olympus scopes with their 4-way connector ( p < 0.001). Proximal connector designs showed a high degree of variability in the number of available Luer locks, valves, seals, angles, and rotative characteristics. The measured length of the working channel of bare scopes ranged between 739 and 854 mm and significantly correlated with measured IDS ( R2 = 0.82, p < 0.001). The coupling of scopes with an alternative ancillary proximal connector and the insertion of ancillary devices into the working channel significantly reduced IDS (mean IDS reduction of 0.1 to 0.5 ml; p < 0.001).Conclusions:IDS appears as a new parameter that should be considered for future applications of flexible ureteroscopes. A low IDS seems desirable for several clinical applications. The main factors impacting IDS are working channel and proximal connector design, as well as ancillary devices inserted into the working channel. Future studies should clarify how reducing IDS may affect irrigation flow, intrarenal pressure, and direct in-scope suction, as well as evaluate the most desirable proximal connector design properties.

Publisher

SAGE Publications

Subject

Urology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3