Affiliation:
1. The National Environmental Protection Board, Box 1302, S-171 25 Solna, Sweden
Abstract
In April 1986 the Nordic Council of Ministers recommended that the Nordic countries use a specific method for measurements of polychlorinated dibenzo-p-dioxins (PCDD) and dibenzofurans (PCDF) in flue gas emissions from waste combustion. The recommended protocol, which will be re-evaluated in a years time, includes the following. A one week registration period during which the plant is studied by continuous registration of a number of operating and emission parameters. The sampling period is included in this time. A sampling procedure based on a heated filter followed by a condenser, a bottle for the condensate and an adsorbent column. Before the sampling, at least two labelled PCDD are added to the filter. No specified analytical procedure. A labelled PCDF is added before the clean-up procedure and an injection standard before the final analysis. The laboratory is free to use any method that gives at least 25% recovery of the sampling standards and 50% recovery of the clean-up standard. Reporting requirements include homologue specific results for PCDD and PCDF containing four to eight chlorine atoms as well as isomer-specific results for the "dirty dozen". The results should be compensated for incomplete recoveries and the factors used should be reported.
Subject
Pollution,Environmental Engineering
Cited by
16 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献