Bicortical versus unicortical fixation of plated clavicular fractures: A biomechanical study

Author:

Zaidenberg Ezequiel E12ORCID,Voor Michael3,Pereira Enrique4,Rossi Luciano A1ORCID,Zaidenberg Carlos R2

Affiliation:

1. Department of Orthopaedics, Italian Hospital of Buenos Aires, Buenos Aires, Argentina

2. Anatomy Department, School of Medicine, University of Buenos Aires, Buenos Aires, Argentina

3. Department of Orthopaedics, Bioengineering Laboratory, University of Louisville, Louisville, USA

4. Department of Orthopaedics, Instituto Argentino de Diagnostico y Tratamiento, Buenos Aires, Argentina

Abstract

Purpose To compare the biomechanical properties of three plate stabilization techniques for midshaft clavicle fractures: anatomical bicortical locking construct, anatomical unicortical locking construct, and reconstruction bicortical locking construct. Methods We analyzed superior plating of the clavicle using an anatomical clavicle plate (Acumed) with both bicortical or unicortical screw fixation and a locking reconstruction plate (DePuy-Synthes). Twenty-one fourth generation composite clavicles were used for non-destructive stiffness testing in axial loading, bending, and torsion. Fifteen composite clavicles and 17 foam clavicles were used for cyclic failure testing using a combined loading method that included all three loading modes. Results No significant differences were found between the three constructs in torsional stiffness nor in vertical bending loading. In axial loading, the anatomical bicortical locking construct was significantly stiffer than either anatomical unicortical locking construct or the reconstruction bicortical locking construct. The unicortical fixation was also significantly stiffer than the reconstruction bicortical locking construct. Regarding failure testing, there was not a significant difference between the bicortical and unicortical anatomical locking constructs; however, both were significantly stronger than bicortical screw fixation in the reconstruction plate. Conclusion Based on the biomechanical performance of these constructs, unicortical locked plate fixation may be a reasonable option in the treatment of displaced midshaft clavicle fracture fixation.

Funder

Acumed

Publisher

SAGE Publications

Subject

Rehabilitation,Physical Therapy, Sports Therapy and Rehabilitation,Orthopedics and Sports Medicine,Surgery

Cited by 6 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3