Reassessing the minimum two-year follow-up standard after total shoulder arthroplasty—Is one year sufficient?

Author:

Mahendraraj Kuhan A12,Carducci Michael P12,Galvin Joseph W3,Golenbock Samuel W4ORCID,Grubhofer Florian3,Jawa Andrew12ORCID

Affiliation:

1. Department of Orthopaedic Surgery, New England Baptist Hospital, Boston, MA, USA

2. Boston Sports and Shoulder Center, Waltham, MA, USA

3. Department of Orthopaedic Surgery, Massachusetts General Hospital, Boston, MA, USA

4. Department of Orthopaedic Research, New England Baptist, Boston, MA, USA

Abstract

Background US Food and Drug Administration Investigation Device Exemption studies and academic journals emphasize the importance of two-year follow-up data in reporting outcomes of total shoulder arthroplasty, but there is limited data evaluating appropriate follow-up length. We aim to evaluate change in postoperative outcomes and complications between one and two years following anatomic and reverse total shoulder arthroplasties. Methods We retrospectively identified 250 patients who underwent anatomic and reverse total shoulder arthroplasties between 2013 and 2016 from a single surgeon arthroplasty registry. Patients without both one- and two-year follow-up data were excluded. We compared American Shoulder and Elbow Surgeons (ASES) score, Visual Analog Scale for pain, and goniometer-measured range of motion. Results Patient-reported outcome measurements ( p > 0.05) did not change between one and two years postoperatively following both reverse ( n = 146) and anatomic ( n = 104) total shoulder arthroplasties. Range of motion increased slightly ( p < 0.05), but this change was not clinically relevant. There were no additional complications. Discussion Minimum two-year clinical follow-up may not be necessary for future shoulder arthroplasty Investigation Device Exemption and other peer-reviewed investigations. Patient-reported outcomes (ASES and pain score) and range of motion plateau at one year postoperatively without additional complications. One-year follow-up is an acceptable minimum follow-up length. Level of evidence Level III—retrospective analysis.

Publisher

SAGE Publications

Subject

Rehabilitation,Physical Therapy, Sports Therapy and Rehabilitation,Orthopedics and Sports Medicine,Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3