Interobserver reliability of radiographic assessment after radial head arthroplasty

Author:

Bexkens Rens123,Claessen Femke M. A. P.1,Kodde Izaäk F.12,Oh Luke S.3,Eygendaal Denise12,van den Bekerom Michel P. J.4

Affiliation:

1. Department of Orthopaedic Surgery, Academic Medical Center, Amsterdam, The Netherlands

2. Department of Orthopaedic Surgery, Amphia Hospital, Breda, The Netherlands

3. Department of Orthopaedic Surgery, Sports Medicine Service, Massachusetts General Hospital, Boston, MA, USA

4. Department of Orthopaedic Surgery, Shoulder and Elbow Unit, Onze Lieve Vrouwe Gasthuis, Amsterdam, The Netherlands

Abstract

Background Radiographs are part of routine clinical care after radial head arthroplasty (RHA). Therefore, the aim of this diagnostic study was to assess the interobserver reliability of radiographic assessment following RHA. Methods Anteroposterior (AP) and lateral radiographs of 24 consecutive patients who underwent press-fit bipolar RHA were evaluated with respect to 14 parameters by 14 orthopaedic surgeons specializing in the elbow: shaft loosening (AP, lateral), subcollar bone resorption, nonbridging heterotopic ossification, capitellar erosion, capitellar osteopenia, implant size, ulnohumeral joint gapping, ulnohumeral joint degeneration, proximal radio-ulnar joint congruency, stem size, stem positioning (AP, lateral) and component dissociation or polyethylene wear of the head with increased angulation. Observer agreement was evaluated using the multirater kappa (κ) measure. Results Nine of 14 parameters had poor interobserver agreement [κ = 0.0 to 0.20, confidence interval (CI) = 0.0 to 0.31). Four parameters had fair agreement: subcollar bone resorption (κ = 0.27, CI = 0.12 to 0.40), capitellar erosion (κ = 0.30, CI = 0.20 to 0.40), ulnohumeral joint degeneration (κ = 0.35, CI = 0.22 to 0.51) and stem positioning in AP view (κ = 0.24, CI = 0.14 to 0.36). One parameter had moderate agreement: nonbridging heterotopic ossification (κ = 0.47, CI = 0.31 to 0.64). Conclusions The overall interobserver reliability of radiographic assessment following press-fit bipolar RHA was poor among experienced elbow surgeons. Therefore, radiographic evaluation after RHA should be interpreted with caution when making treatment decisions.

Publisher

SAGE Publications

Subject

Rehabilitation,Physical Therapy, Sports Therapy and Rehabilitation,Orthopedics and Sports Medicine,Surgery