Affiliation:
1. Bristol Royal Infirmary, University Hospitals Bristol and Weston NHS Foundation Trust, Bristol, UK
Abstract
Background Distal biceps rupture presents with an increasing incidence and evidence suggests that although a surgical repair is not mandatory, it results in superior functional outcomes when compared to non-operative management. As implant technology has advanced, several devices have been utilised and studied in managing this pathology. We present our single-centre experience with the use of the ToggleLoc Ziploop reattachment device, a knotless cortical button implant, using a single-incision technique. Methods Retrospective series of 70 consecutive distal biceps tendon repairs, at a mean follow-up of 45.6 months after surgery, using a standardised single implant, single-incision technique, and post-operative rehabilitation programme. Results There was one (1.4%) re-rupture in our patient cohort. The range of motion was complete in all patients except for one patient who had symptomatic heterotopic ossification, causing limitation in pronation. Complications were minor with the commonest being transient neuropraxia of the lateral cutaneous nerve of the forearm. The mean Oxford elbow score was 46.9 out of 48, and the patient global impression of change scale was 7 out of 7 in 77% of cases. Conclusion Our data support this technique and implant combination when dealing with acute and chronic distal biceps tendon rupture.
Subject
Rehabilitation,Physical Therapy, Sports Therapy and Rehabilitation,Orthopedics and Sports Medicine,Surgery
Cited by
1 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献
1. Shoulder & Elbow;Bone & Joint 360;2023-02