Affiliation:
1. Department of Electrical Power and Machines, Faculty of Engineering, Zagazig University, Zagazig, Egypt
Abstract
In this paper, a new concurrent unity power factor and constant stator flux linkage (UPF-CFL) control is presented. The main goal of this technique is to introduce the Permanent Magnet Synchronous Generator (PMSG) as an optimal wind energy transducer. The handled generator load angle and back EMF control achieve the optimum requirements for wind applications namely Maximum Power Point Tracking (MPPT). To do this, both UPF and CFL are integrated into one control methodology to obtain the advantages of each one. While the first well utilizes the apparent power increasing the generator side converter capability, the second protects the generator against magnetic saturation to enable higher speed operation. Mathematical model based on constant current fed equivalent circuit is presented taking the constraints of each individual control algorithm into account. The concurrent performance characteristics are presented and compared with each of concurrent separated algorithm characteristics for assessments. The control technique is implemented and finally, simulation testing is provided for evaluation.
Subject
Energy Engineering and Power Technology,Renewable Energy, Sustainability and the Environment
Cited by
4 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献