Sonographic parameters for diagnosing fetal head engagement during labour

Author:

Wiafe Yaw A12,Whitehead Bill1,Venables Heather1,Odoi Alexander T3

Affiliation:

1. Department of Nursing, Radiography and Healthcare, University of Derby, Derby, UK

2. Department of Sonography, Faculty of Allied Health Sciences, Kwame Nkrumah University of Science and Technology, Kumasi, Ghana

3. Department of Obstetrics and Gynaecology, School of Medical Sciences, Kwame Nkrumah University of Science and Technology and Komfo Anokye Teaching Hospital, Kumasi, Ghana

Abstract

The purpose of this study was to investigate the diagnostic performance of the head–perineum distance, angle of progression, and the head–symphysis distance as intrapartum ultrasound parameters in the determination of an engaged fetal head. Two hundred and one women in labour underwent both ultrasound and digital vaginal examination in the estimation of fetal head station. The transperineal ultrasound measured head–perineum distance, angle of progression, and head–symphysis distance for values correlating with digital vaginal examination head station. Using station 0 as the minimum level of head engagement, correlating cut-off values for head–perineum distance, angle of progression, and head–symphysis distance were obtained. Receiver operating characteristics were used in determining the diagnostic performance of these cut-off values for the detection of fetal head engagement. With head–perineum distance of 3.6 cm the sensitivity and specificity of sonographic determination of engaged fetal head were 78.7 and 72.3%, respectively. A head–symphysis distance of 2.8 cm also had sensitivity and specificity of 74.5 and 70.8%, respectively, in determining engagement, whilst an angle of progression of 101° was consistent with engagement by digital vaginal examination with 68.1% sensitivity and 68.2% specificity. Ultrasound shows high diagnostic performance in determining engaged fetal head at a head–perineum distance of ≤3.6 cm, head–symphysis distance of ≤2.8 cm, and angle of progression of ≥ 101°.

Publisher

SAGE Publications

Subject

Radiology Nuclear Medicine and imaging,Radiological and Ultrasound Technology

Cited by 12 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司