Abstract

Ultrasound image degradation originates primarily from transducer defects and potentially undermines reliable image interpretation. Systematic quantitative quality control is often neglected due to the limited resources available for this task. We propose a quantitative quality control based on in-air reverberation images. These images serve as an initial indication of image degradation. They are easily generated for any (curvi-)linear transducer independent of the level of expertise of the operator. Automated analysis is presented to extract quality parameters based on the in-air reverberation pattern. Static images acquired by the clinical user are transferred to a server where analysis is performed. The results are available to the sonographer prior to clinical use and transducer status can be remotely monitored with trend analysis over time. The method was evaluated for normal functioning and defect transducers. A pilot study was performed over a period of three weeks to assess reproducibility and practical feasibility. All reverberation images were successfully analysed for different transducer types and vendor-specific image presentation. The proposed quality parameters are sensitive to signal loss and allow differentiation of type and severity of image degradation. The pilot study was well received by the sonographers for the simplicity of the method and the measurements were consistent over time. The proposed automated analysis method of ultrasound quality control can monitor (curvi-)linear transducer status in the entire hospital, overcoming previous limitations for periodic quality control. Implementation of the method can reduce the number of defective transducers routinely used in clinical practice.

Publisher

SAGE Publications

Subject

Radiology, Nuclear Medicine and imaging,Radiological and Ultrasound Technology

Cited by 6 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3