Does matrix transducer technology improve quality and repeatability of four-dimensional tricuspid annular plane systolic excursion and mitral annular plane systolic excursion measurements?

Author:

Thomas Samantha12ORCID,Erenbourg Anna1,Chang Melissa1,Ferreira Ana Gomes de Melo Tavares1,Stevenson Gordon1,Welsh Alec13

Affiliation:

1. School of Clinical Medicine, Discipline of Women’s Health, Faculty of Medicine, University of New South Wales, Sydney, NSW, Australia

2. Level 0, Royal Hospital for Women, Randwick, NSW, Australia

3. Department of Maternal-Fetal Medicine, Royal Hospital for Women, Sydney, NSW, Australia

Abstract

Background: Novel ultrasound technology and software processing allow offline evaluation of tricuspid annular plane systolic excursion and mitral annular plane systolic excursion measurements. We wished to compare both novel 4D matrix (eM6C) and conventional (RAB6-D) transducers with variable settings (electronic spatiotemporal image correlation, spatiotemporal image correlation and four-dimensional real time) to determine if there was a significant difference in absolute value, quality and repeatability of the resultant reconstructed image and M-mode trace. Methods: A blinded prospective cross-sectional study of normal fetuses from 23 to 38 weeks’ gestation were recruited. After routine sonography, four-dimensional volumes were stored and analysed using GE 4DView™ software. Statistical analysis explored variability, correlations and repeatability of the measurements with chi-square analysis, intraclass correlations and the Bland–Altman comparison plots. A scoring system was devised for image quality. Results: Eighteen participants generated 282 data volumes. Absolute values demonstrated some inconsistencies for both tricuspid annular plane systolic excursion and mitral annular plane systolic excursion measurements with variations between transducers: the highest for the RAB6-D/spatiotemporal image correlation setting and the lowest for the four-dimensional real-time settings. The RAB6-D/spatiotemporal image correlation setting was the most repeatable combination (intraclass correlation coefficient = 0.85). Poorest image quality (M-mode trace, four-chamber view, annuli) came from the RAB6-D/four-dimensional real-time combination with the eM6C/electronic spatiotemporal image correlation and RAB6-D/spatiotemporal image correlation settings being nearly identical. Conclusion: We show that transducer and setting combinations influence absolute tricuspid annular plane systolic excursion/mitral annular plane systolic excursion measurements, so need to be articulated in future research. The transducer setting (electronic spatiotemporal image correlation/spatiotemporal image correlation/four-dimensional real time) was a more significant factor than the type of transducer (conventional vs matrix). Subjective image evaluation does not correlate well with repeatability of image acquisition. Further studies are needed to compare measurements using four-dimensional post-processing tools against conventional real-time measurements.

Funder

eM6C probe loan from GE Healthcare

Publisher

SAGE Publications