Evaluating the effectiveness of a lower extremity venous phantom on developing ultrasound examination skills and confidence

Author:

Mitchell Carol1ORCID,Xiong Pazee L23,Cox Benjamin L23,Adoe Maame A4,Cordio Michelle M56,Quade Tonya R567,Petry George2,Eliceiri Kevin W238

Affiliation:

1. Department of Medicine, Division of Cardiovascular Medicine, University of Wisconsin-Madison, School of Medicine and Public Health, Madison, WI, USA

2. Morgridge Institute for Research, Madison, WI, USA

3. Department of Biomedical Engineering, College of Engineering, University of Wisconsin-Madison, Madison, WI, USA

4. University of Wisconsin Hospital and Clinics, Echo/Vascular Lab, Madison, WI, USA

5. Department of Human Resources, University of Wisconsin Hospital and Clinics School of Diagnostic Medical Sonography, Madison, WI, USA

6. Department of Radiology, University of Wisconsin-Madison, School of Medicine and Public Health, Madison, WI, USA

7. SSM Health, Waupun Memorial Hospital and Ripon Medical Center, Ripon, WI, USA

8. Department of Medical Physics, University of Wisconsin School of Medicine and Public Health, University of Wisconsin-Madison, Madison, WI, USA

Abstract

Introduction The aims of this study were: (1) Determine the effect on student ultrasound scanning skills using a lower extremity venous ultrasound phantom in addition to standard teaching methods of didactic lecture and scanning live volunteers and (2) Determine the effect of using a lower extremity venous ultrasound phantom in addition to standard teaching methods of didactic lecture and scanning live volunteers on student confidence levels in performing the lower extremity venous ultrasound examination. Methods Participants were first year diagnostic medical sonography students with minimal scanning experience ( n = 11), which were randomized into two groups. Group 1 ( n = 5) received the standard didactic lecture and attended a scan lab assessment where they performed a lower extremity venous examination on a human volunteer. Group 2 ( n = 6) received the standard didactic lecture, performed three scheduled scanning sessions on an anatomic lower extremity venous phantom with flow and then attended the same scan lab assessment as Group 1, where they performed a lower extremity venous examination on a human volunteer. Results Scan lab assessments on day 4 of the study demonstrated a significant difference in scanning performance ( p = 0.019) between the two groups. Post scan lab assessment confidence scores also demonstrated a significant difference between how participants in each group scored their confidence levels ( p = 0.0260), especially in the ability to image calf veins. Conclusions This study suggests anatomical phantoms can be used to develop scanning skills and build confidence in ultrasound imaging of the lower extremity venous structures.

Funder

• This project was supported by funding from the Berbee Walsh Prototype Pathway program at the Morgridge Institute for Research.

Publisher

SAGE Publications

Subject

Radiology Nuclear Medicine and imaging,Radiological and Ultrasound Technology

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3