Affiliation:
1. Department of Mechanical and Industrial Engineering, University of Toronto, Canada
Abstract
The increasing demand for vibration reduction in several high-tech industries has motivated many researchers to investigate novel vibration isolation techniques. Understanding the vibration transfer paths within a system is an essential part of designing an effective vibration isolation strategy. In this paper, an analytical transfer path analysis algorithm is proposed suitable for multi-energy-domain systems. The bond graph modeling technique, which is an effective approach to model multi-energy-domain systems, is used to extend the concept of transmissibility to such systems. In this paper, an electro-hydro-mechanical system is used as a benchmark example to elucidate the effectiveness of the proposed technique. An energy based path ranking algorithm based on the bond graph model of the system is also conducted.
Subject
Mechanical Engineering,Mechanics of Materials,Aerospace Engineering,Automotive Engineering,General Materials Science
Cited by
5 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献