Abstract
The boring operation is prone to chatter as the boring bar is slender and has an overhang. For chatter suppression, passive, semi-active or active control methods can be employed. In the present work, a boring bar has been specially designed to transfer vibration to a cantilever bar surrounded by magneto rheological (MR) fluid. The MR fluid when exposed to electromagnetic flux changes its rheological property within a certain range. Thus, the boring bar is able to exhibit variable damping characteristics by changing the excitation current. The modal parameters are experimentally obtained through an impact test and a shaker test. The variation of modal parameters with excitation current is discussed. A stability lobe diagram is also developed from the model parameters, showing safe and unsafe regions for operation. The semi-active boring bar developed in the present work can be used for the suppression of chatter during the boring operation.