Comparison of Volatile Sulfur Compound Concentrations Measured with a Sulfide Detector vs. Gas Chromatography

Author:

Furne J.123,Majerus G.123,Lenton P.123,Springfield J.123,Levitt D.G.123,Levitt M.D.123

Affiliation:

1. The Minneapolis Veterans Affairs Medical Center -151-, 1 Veterans Drive, Minneapolis, MN 55417;

2. Department of Medicine, University of Minnesota; and

3. Dental School, Preventive Sciences, University of Minnesota;

Abstract

The accuracy of the Halimeter®, an inexpensive, simple instrument that measures total breath volatile sulfur compounds (VSCs), has not been adequately tested. We compared Halimeter® measurements with those obtained with a specific and sensitive gas chromatographic (GC) technique. The Halimeter® gave different, bi-exponential responses to a constant concentration of different VSCs: The relative response rate and sensitivity were hydrogen sulfide > methyl mercaptan > dimethylsulfide. The transient peak VSC concentration of oral samples was reached long before the sulfide detector fully responded. The GC measurement of initial total VSCs in breath samples was 2.7 ± 0.48 times greater than the peak concentration of the Halimeter®. However, the plateau phase measurement of the Halimeter® was 25% greater than that of GC. While GC and Halimeter® measurements positively correlated, appreciable differences were observed. In studies where relatively precise VSC measurements are required, GC is the preferable technique.

Publisher

SAGE Publications

Subject

General Dentistry

Reference12 articles.

1. Frascella J, Gilbert R, Fernandez P, Hendler J -2000- Efficacy of a chlorine dioxide containing mouth rinse in oral malodor. Compend Contin Educ Dent 21:241–254.

2. Niles H, Gaffar S -1993- Relationship between sensory and instrumental evaluation of mouth odor. J Soc Cosmet Chem 44:101–107.

3. Richter J -1996- Diagnosis and treatment of halitosis. Compend Contin Educ Dent 17:370–386.

4. Measurement of Oral Malodor: Current Methods and Future Prospects

5. Reproducibility and Sensitivity of Oral Malodor Measurements with a Portable Sulphide Monitor

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3