Current Surgical Risk Scores Overestimate Risk in Minimally Invasive Aortic Valve Replacement

Author:

Alnajar Ahmed1ORCID,Chatterjee Subhasis23,Chou Brendan P.2,Khabsa Mariam2,Rippstein Madeline2,Lee Vei-Vei3,La Pietra Angelo4,Lamelas Joseph1234

Affiliation:

1. Division of Cardiothoracic Surgery, University of Miami, FL, USA

2. Division of Cardiothoracic Surgery, Michael E. DeBakey Department of Surgery, Baylor College of Medicine, Houston, TX, USA

3. Department of Cardiovascular Surgery, Texas Heart Institute, Houston, TX, USA

4. Division of Cardiothoracic Surgery, Mount Sinai Medical Center and Heart Institute, Miami Beach, FL, USA

Abstract

Objective Risk-scoring systems for surgical aortic valve replacement (AVR) were largely derived from sternotomy cases. We evaluated the accuracy of current risk scores in predicting outcomes after minimally invasive AVR (mini-AVR). Because transcatheter AVR (TAVR) is being considered for use in low-risk patients with aortic stenosis, accurate mini-AVR risk assessment is necessary. Methods We reviewed 1,018 consecutive isolated mini-AVR cases (2009 to 2015). After excluding patients with Society of Thoracic Surgeons Predicted Risk of Mortality (STS-PROM) scores ≥4, we calculated each patient’s European System for Cardiac Operative Risk Evaluation (EuroSCORE) II, TAVR Risk Score (TAVR-RS), and age, creatinine, and ejection fraction score (ACEF). We compared all 4 scores’ accuracy in predicting mini-AVR 30-day mortality by computing each score’s observed-to-expected mortality ratio (O:E). Area under the receiver operating characteristic (ROC) curves tested discrimination, and the Hosmer–Lemeshow goodness-of-fit tested calibration. Results Among 941 patients (mean age, 72 ± 12 years), 6 deaths occurred within 30 days (actual mortality rate, 0.6%). All 4 scoring systems overpredicted expected mortality after mini-AVR: ACEF (1.4%), EuroSCORE II (1.9%), STS-PROM (2.0%), and TAVR-RS (2.1%). STS-PROM best estimated risk for patients with STS-PROM scores 0 to <1 (0.6 O:E), ACEF for patients with STS-PROM scores 2 to <3 (0.6 O:E), and TAVR-RS for patients with STS-PROM scores 3 to <4 (0.7 O:E). ROC curves showed only fair discrimination and calibration across all risk scores. Conclusions In low-risk patients who underwent mini-AVR, current surgical scoring systems overpredicted mortality 2-to-3-fold. Alternative dedicated scoring systems for mini-AVR are needed for more accurate outcomes assessment.

Publisher

SAGE Publications

Subject

Cardiology and Cardiovascular Medicine,General Medicine,Surgery,Pulmonary and Respiratory Medicine

Cited by 10 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3