Automated Suture Fastener Gaining Complete Commitment: Cumulative Propensity-Matched Comparison with Hand-Tied Knot in Heart Valve Surgery

Author:

Ler Ashlynn12,Wu Duoduo13,Xian Ong Zhi13,Sazzad Faizus134ORCID,Swee Kang Giap135,Kofidis Theo1345ORCID

Affiliation:

1. Department of Cardiac, Thoracic and Vascular Surgery, National University Hospital, Singapore

2. School of Medicine, National University of Ireland, Galway, Ireland

3. Department of Surgery, Yong Loo Lin School of Medicine, National University of Singapore, Singapore

4. Cardiovascular Research Institute, National University of Singapore, Singapore

5. National University Heart Center, National University Health System, Singapore

Abstract

Objective The COR-KNOT® device is an automated suture fastener in which there is currently no consensus on its role in heart valve surgery. Our aim was thus to conduct a one-to-one comparison of clinical outcomes with a hand-tied control cohort. Methods We performed a single-center, cumulative propensity-matched retrospective cohort study on patients undergoing heart valve surgery from 1 January 2015 to 13 February 2020. Propensity score matching was performed on 693 patients, dividing them into matched COR-KNOT® ( n = 124) and hand-tied ( n = 124) groups. Results Data on baseline demographics, operative details, and clinical outcomes were analyzed and compared between the groups. The patients in both the COR-KNOT® and control groups were well-matched. For the median sternotomy (MS) all procedures subgroup, use of COR-KNOT® was associated with a decrease of around 49 min in CPB time (220.00 [168.00 to 256.00] vs 70.50 [134.00 to 236.75] min, P = 0.006) and around 32 min in ACC time (145.00 [109.00 to 189.00] vs 112.50 [81.00 to 161.75] min, P = 0.008). In the MS valve and CABG subgroup, use of COR-KNOT® was associated with a 70 min reduction in overall operation time (401.00 [354.25 to 468.75] vs 330.50 [288.50 to 370.50] min, P = 0.013), 63 min reduction in CPB time (216.50 [191.75 to 283.25] vs 153.00 [124.75 to 207.50] min, P = 0.004) and 45 min reduction in ACC time (146.00 [134.50 to 205.50] vs 100.50 [71.50 to 150.75] min, P = 0.003). Conclusions In heart valve surgery, use of the automated suture fastener was associated with shorter CPB and ACC times. Additionally, we determined that clinical outcomes are most likely unaffected by the use of COR-KNOT®.

Publisher

SAGE Publications

Subject

Cardiology and Cardiovascular Medicine,General Medicine,Surgery,Pulmonary and Respiratory Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3