Analysis of Facial Muscle Depths to Guide Botulinum Toxin Therapy of the Periocular Region

Author:

Mowlavi Arian S.1ORCID,Van Alstine Rebecca L.2,Berri Mariam3,Arshad Samar4,Ablavsky Michael5,Kachare Swapnil5,Wilhelmi Bradon J.6

Affiliation:

1. Cosmetic Plastic Surgery Institute, Laguna Beach, CA, USA

2. Ross University School of Medicine, Bridgetown, Barbados

3. California Health Sciences University College of Osteopathic Medicine, Clovis, USA

4. University of California, Irvine, USA

5. University of Louisville, KY, USA

6. Chief of Plastic Surgery, University of Louisville, KY, USA

Abstract

Purpose: Botulinum toxin (BTX) injections are used in cosmetic surgery to efface facial wrinkles. Botulinum toxin relaxes the muscle by preventing the release of the neurotransmitter acetylcholine at the neuromuscular junction located at the posterior muscle surface causing local muscle paralysis. The purpose of this study is to provide anatomic knowledge of muscle belly depths of the frontalis, corrugator supercilii, procerus, and orbicularis oculi muscles in an attempt to improve the efficacy of BTX treatment of glabellar, forehead, and lateral eyelid rhytides. Methods: Six-millimeter punch biopsies were obtained from 7 fresh cadavers. Biopsies were taken from the corrugator supercilii, frontalis, procerus, and orbicularis oculi muscles at the sites of routine BTX injection. Specimens were fixed in formalin, and representative H&E-stained sections were used to measure muscle surface depths by light microscopy equipped with digital camera that includes a digital micrometer. One-way analysis of variance test analyses were used to identify statistical differences between measured muscle depths. Results: The measured anterior muscle depth of the corrugator supercilii, frontalis, procerus, and orbicularis oculi was found to be 4.2 ± 0.6, 3.9 ± 0.6, 2.9 ± 0.4, and 2.3 ± 0.7 mm, respectively. The anterior muscle surface of the corrugator supercilii and frontalis was found to be deeper than that of the procerus and orbicularis oculi ( P < .001). The posterior surface depth of the corrugator supercilii, frontalis, procerus, and orbicularis oculi was found to be 6.6 ± 0.8, 5.1 ± 0.7, 4.9 ± 0.7, and 3.8 ± 1.0 mm, respectively. The posterior surface depth of the corrugator supercilii was found to be significantly deeper than that of the frontalis, procerus, and orbicularis oculi ( P < .001); the posterior surface depth of the frontalis and procerus was deeper than that of the orbicularis oculi ( P < .001). The muscle belly width of the corrugator supercilii, frontalis, procerus, and orbicularis oculi measured 2.5 ± 0.9, 1.1 ± 0.4, 2.0 ± 0.6, and 1.5 ± 0.5 mm, respectively. The corrugator supercilii was found to be thicker than the frontalis and orbicularis oculi, while the procerus was found to be thicker than the frontalis ( P < .001). Conclusion: The findings above demonstrate statistical differences in the posterior muscle surface depth of the corrugator supercilii, frontalis, procerus, and orbicularis oculi which can be used clinically to improve BTX injection efficacy when used to efface facial rhytides.

Publisher

SAGE Publications

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3