Autologous Fat Transfer: Eliminating the Centrifuge, Decreasing Lipocyte Trauma and Establishing Standardization for Scientific Study

Author:

Shippert Ron D.

Abstract

Introduction: The autologous fat transfer procedure has undergone a renewal of interest because of the need for larger quantities of economical filler (face, buttocks, hands, and breasts). Commercial fillers are cost prohibitive when large quantities are needed. Present instruments on the market are not specialized enough to perform well during the autologous fat transfer procedure. As a result, multiple techniques have evolved that produce extremely varied results that are not scientifically verifiable. The objectives of this paper are to (1) review the events that are traumatic for the lipocyte and review how those events can be improved through new instrumentation; (2) review the use of the centrifuge and consider replacement of the centrifuge with an effective filter system; (3) establish instrument standards that will encourage scientific technique verification; and (4) introduce a standardized autologous fat transfer instrument that will save time, reduce significant trauma, and have standardized features to promote accurate scientific study. Methods: Information was obtained via a questionnaire, internet investigation, trade show information, personal discussions with surgeons, and the author's experience. Information from the questionnaire was used in the design of a new, improved standardized instrument. Results: During this study, an instrument was designed that would reduce operating room time considerably. Most of the time reduction was secondary to keeping the fat in the harvest syringe without transferring or centrifuging. This change in procedure would also considerably reduce lipocyte trauma in all 12 of the commonly accepted lipocyte trauma categories. In addition, the instrument could be standardized with multiple features that would give the surgeon confidence that the surgical results would not change because of the instruments. Conclusions: The Tissu-Trans™ device that was designed during this study significantly saves time, simplifies the procedure, and has standardized features that allow for scientific studies that are more accurate. The equipment offers simplicity and “feature latitude,” allowing the surgeon to perform all of the major steps (harvest, filter, irrigate, treatment, and reinjection) from a single harvest syringe. Although all 12 of the traumatic events for lipocytes were reduced in intensity, one should not leap to the conclusion that this correlates with increased lipocyte survival. To date, this has not been proven. Further clinical testing will be necessary to obtain this information.

Publisher

SAGE Publications

Cited by 15 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Current Techniques;Autologous fat tissue transfer;2019

2. Autologous Fat Grafting to the Breast Using REVOLVE System to Reduce Clinical Costs;Annals of Plastic Surgery;2016-09

3. Gängige Techniken;Autologe Fettgewebstransplantation;2016

4. Methoden des Fetttransfers;Journal für Ästhetische Chirurgie;2015-07

5. Hand Rejuvenation with Stem Cell Fat Transfer;Stem Cells in Aesthetic Procedures;2014

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3