Affiliation:
1. From the Departments of Otolaryngology, Wayne State University
2. Audiology, Wayne State University
Abstract
Cis-platinum–induced hearing loss has been reported to exhibit a “plateau effect” over the 2 to 8 kHz range. We examined serial audiometry data from 27 patients treated with cis-platinum. Although a plateau at 60 to 70 dB HL often occurred, this hearing loss was clearly exceeded in a number of patients. We identified 14 patients with sufficient cis-platinum-induced sensorineural hearing loss to evaluate a plateau limit to hearing loss over the 4 to 8 kHz range. Half of these 14 patients had hearing losses that exceeded the plateau level. More severe 4 to 8 kHz hearing losses did not correlate with number of treatments, cumulative dosages of cis-platinum, pre-existing hearing loss, radiation therapy, other chemotherapeutic agents, or even hearing losses below 4 kHz. Although cis-platinum therapy can induce a plateau of moderate hearing impairment for some patients over the 4 to 8 kHz range, a significant proportion of patients will experience more severe hearing impairment in this range, even after only one or two courses Of cis-platinum.
Subject
Otorhinolaryngology,Surgery
Cited by
18 articles.