Robotic-Assisted Parathyroidectomy

Author:

Tolley Neil1,Arora Asit1,Palazzo Fausto2,Garas George1,Dhawan Ranju3,Cox Jeremy4,Darzi Ara5

Affiliation:

1. Department of Otorhinolaryngology and Head & Neck Surgery, St Mary’s Hospital, Imperial College Healthcare NHS Trust, London, UK

2. Department of Endocrine and Thyroid Surgery, Hammersmith Hospital, Imperial College Healthcare NHS Trust, London, UK

3. Department of Radiology, St Mary’s Hospital, Imperial College Healthcare NHS Trust, London, UK

4. Department of Endocrinology, St Mary’s Hospital, Imperial College Healthcare NHS Trust, London, UK

5. Department of Biosurgery and Surgical Technology, St Mary’s Hospital, Imperial College London, London, UK

Abstract

Objective. Targeted parathyroidectomy is the gold standard for localized parathyroid disease. A robotic-assisted approach has not been investigated. The aim was to assess the feasibility of a robotic technique that avoids a neck scar. Study Design. Feasibility study. Setting. Tertiary referral center. Subjects and Methods. Eleven patients with primary hyperparathyroidism were prospectively evaluated. Triple modality concordant localization was a prerequisite. All patients underwent robotic-assisted parathyroidectomy (RAP). Outcome variables assessed were operative time, voice change, biochemical cure, and histopathological confirmation. Patient-reported outcome measures (PROMs) included subjective assessment of pain and scar cosmesis, Voice Handicap Index 2, and EQ-5D quality-of-life assessment. Mean follow-up was 6 months (range, 3-12 months). Results. The parathyroid adenoma was successfully excised in all cases with negligible blood loss (<5 mL). There was 1 conversion. There was no voice change in any case. Robot docking time plateaued to 10 minutes after 8 cases. Mean exposure and console times (31 and 51 minutes, respectively) were affected by body habitus. The mean visual analog scale for scar cosmesis was 75% on the first postoperative day, improving to 92% at 6 months and 95% at 1 year. Pain scores decreased to 8% at 2 weeks. All 5 EQ-5D quality-of-life parameters significantly improved following surgery. Conclusion. The robotic approach is feasible for performing targeted parathyroidectomy that avoids a neck scar. The clinical efficacy and cost-effectiveness of the robotic approach compared with conventional targeted parathyroidectomy warrant further evaluation to establish if this represents a viable alternative to the existing targeted techniques.

Publisher

SAGE Publications

Subject

Otorhinolaryngology,Surgery

Cited by 57 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3