A Comparison of Laser-Protected Endotracheal Tubes

Author:

Burns James A.1,Adlard Stephen D.1,Kobler James B.1,Tynan Monica A.1,Petrillo Robert H.1,Tracy Lauren F.1

Affiliation:

1. Center for Laryngeal Surgery and Voice Rehabilitation, Department of Surgery, Harvard Medical School, Massachusetts General Hospital, Boston, Massachusetts, USA

Abstract

Objectives To compare the physical characteristics of 3 laser-protected endotracheal tubes (LPETs) commonly used in endoscopic laser surgery. To report potential intraoperative problems related to LPET use and suggest practical solutions. Study Design Comparative analysis. Setting Academic laboratory. Subjects and Methods Physical characteristics of the Mallinckrodt Laser-Flex (MTL), Medtronic Laser-Shield II (ML-II), and Rusch LaserTubus (RL) were compared. The effect of bending LPETs on airflow resistance was estimated with a pressure transducer. The force required to pull each tube through the glottis and the pressure exerted during this maneuver were measured in a fresh cadaveric human larynx. Results The design features and physical characteristics of LPETs differ, including varying balloon-tip lengths. Bending LPETs to acute angles caused significant pressure increase within the RL tube (Δ 3.42 cm H2O) and minimal change within the ML-II (Δ 0.12 cm H2O) and MTL (Δ 0.21 cm H2O) tubes. The average force required to pull the RL (48.12 g, P = .003) and MTL (282.4 g, P = .001) tubes through the glottis was 7.6× and 44.5× greater than that for the ML-II (6.39 g). When pulled through the vocal folds, the ML-II cuff exerted no detectable pressure, whereas higher pressures were measured for the RL (2.2 cm H2O) and MTL (6.5 cm H2O) tubes. Conclusion The ML-II tube had the most favorable characteristics, with minimal pressure during extubation and resistance to kinking. The RL tube kinks readily with a resultant increase in resistance to airflow. The MTL tube extends farther into the trachea due to a relatively elongated balloon-tip configuration. Future LPET designs should incorporate features that avoid intraoperative difficulties related to airway protection and ventilation.

Publisher

SAGE Publications

Subject

Otorhinolaryngology,Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3