Localization of Small Parathyroid Adenomas Using Modified 4-Dimensional Computed Tomography/Ultrasound

Author:

Stucken Emily Z.1,Kutler David I.1,Moquete Rachel1,Kazam Elias12,Kuhel William I.1

Affiliation:

1. Weill Cornell Medical College/New York Presbyterian Hospital, New York, New York, USA

2. Manhattan Diagnostic Radiology, New York, New York, USA

Abstract

Objective. To investigate whether parathyroid gland weight has an impact on the accuracy of preoperative localization of parathyroid adenomas with modified 4 dimensional computed tomography/ultrasound. And to determine if the weight of parathyroid adenomas can be calculated accurately based on the dimensions of the gland on the CT images. Study Design. Case series with chart review. Setting. Tertiary care hospital. Subjects and Methods. One hundred forty-two patients who had a preoperative modified 4-dimensional computed tomography/ultrasound and underwent parathyroidectomy for hyperparathyroidism due to a parathyroid adenoma between 1998 and 2009. Charts were reviewed to identify (1) the sensitivity and specificity for localization of parathyroid adenomas according to gland weight and (2) correlation between preoperative estimate of parathyroid weight and the surgical weight of the parathyroid gland. Results. Modified 4-dimensional computed tomography/ultrasound displayed 92% sensitivity for localizing adenomas weighing <150 mg to the correct side of the neck (95% confidence interval [CI], 65%-99%), 100% sensitivity for glands weighing 150 to 500 mg (95%-100%), and 98% sensitivity for glands weighing >500 mg (92%-100%). For localization to the correct quadrant of the neck, sensitivity was 75% (95% CI, 47%-91%) for glands weighing <150 mg, 89% (79%-95%) for those weighing 150 to 500 mg, and 94% (85%-97%) for glands weighing >500 mg. A positive correlation was seen between the preoperative weight estimate based on imaging and the operative weight of the gland, with a Pearson correlation coefficient of 0.96. Conclusion. Modified 4-dimensional computed tomography/ultrasound can closely predict the weight of parathyroid glands preoperatively and has good sensitivity for localization of adenomas, even in glands weighing less than 150 mg.

Publisher

SAGE Publications

Subject

Otorhinolaryngology,Surgery

Cited by 23 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3