Management of the Incus Body in Ossiculoplasty

Author:

Capra Gregory G.1,Ge Xianxi1,Balough Ben J.2,Shah Anil N.1,Turner Sam3,Mullin David P.1,Pfannenstiel Travis J.4

Affiliation:

1. Department of Otolaryngology, Naval Medical Center San Diego, San Diego, California, USA

2. Kaiser Permanente South Sacramento, Sacramento, California, USA

3. Naval Hospital Camp Lejeune, Camp Lejeune, North Carolina, USA

4. Department of Otolaryngology, San Antonio Military Medical Center, Fort Sam Houston, Texas, USA

Abstract

Objective (1) Evaluate the sound transfer impact of removal of the incus body in ossicular chain reconstruction (OCR) using an incus strut prosthesis. (2) Provide basic science data to assist clinical decision making in ossiculoplasty. Study Design Basic science. Setting Cadaveric temporal bone research laboratory. Subjects and Methods Ossicular chain reconstruction with an incus strut prosthesis was performed on 7 human temporal bones with and without the incus body. The difference in round window membrane (RWM) peak-to-peak displacements (90-dB sound pressure level, 250-8000 Hz) using single-point laser Doppler vibrometry (LDV) was compared with observed baseline, intact ossicular chain values. Results Comparing OCR using an incus strut prosthesis to an intact ossicular chain across all 7 temporal bones, the largest differences in RWM velocity occurred at 1011 and 2011 Hz. With increasing frequencies, RWM velocities of the OCR approached the intact ossicular chain. Using a Wilcoxon rank-sum test comparing the ossicular chain with and without the incus body showed no statistically significant difference across all frequencies ( P = .925). Removing the incus body resulted in improved median RWM velocity (×10−2 mm/s) by 0.6 at 1011 Hz and a decrease of 0.6 at 2011 Hz. A rank-sum test to evaluate the difference at 1011 and 2011 Hz did not demonstrate statistical significance. Conclusion Removal of the incus body in OCR using an incus strut prosthesis did not significantly change sound transfer function of the middle ear relative to its preservation. Our data suggest the impact of the retained mass in OCR to be minimal.

Publisher

SAGE Publications

Subject

Otorhinolaryngology,Surgery

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Corrigendum;Otolaryngology–Head and Neck Surgery;2013-11-20

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3