Objectives Montgomery Safe-T-Tube deterioration and early biofilm colonization may explain the discomfort claimed by many patients and clinical failures. The aim of the study was to analyze the deterioration of Montgomery Safe-T-Tube morphological and mechanical properties in vivo in 16 patients by using microbiological methods, optical and electron microscopy, and engineering tests. Study Design Prospective controlled study at a single medical center. Setting University hospital. Subjects and Methods The study, conducted from April 2007 to February 2012 at the “Sapienza” University of Rome, was designed to collect 2 Montgomery Safe-T-Tubes from each patient. The first was removed 3 to 15 days after insertion (group A) and the second at least 90 days after (group B). Specimens underwent microbiologic assays, electron microscopic analysis, immunocytologic analysis, and mechanical tests. Results Microorganisms were not isolated in 2 group A cases (12%), whereas they were in all group B cases. Biofilm was identified in 11 of 16 (69%) group A samples and in 16 of 16 (100%) group B samples ( P = .0149) using scanning electron microscopy. Immunohistochemistry showed monocyte-granulocyte line cells producing interleukin-1β on the external surfaces of Montgomery Safe-T-Tubes. The tensile test showed that the wear related to the longer period of use makes Montgomery Safe-T-Tubes more rigid than newer ones. Conclusion Early biofilm colonization takes place in Montgomery Safe-T-Tubes in most cases. The mechanical decay could be justified in part by the destructive biofilm activity and by the release of inflammatory effectors and enzymes.

Publisher

SAGE Publications

Subject

Otorhinolaryngology,Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3