Affiliation:
1. NASA Langley Research Center Hampton, Virginia 23665
Abstract
Graphite/epoxy panels with buffer strips were tested in tension to measure their residual strength with crack-like damage. Panels were made with [45/0/-45/90]2 S and [45/0/-45/0]2 S layups. The buffer strips were parallel to the loading direction. They were made by replacing narrow strips of the 0° graphite plies with strips of either 0° S-Glass/epoxy or Kevlar-90/epoxy on either a one-for-one or a two-for-one basis. In a third case, 0° graphite/epoxy was used as the buffer material and thin, perforated Mylar strips were placed between the 0° plies and the cross-plies to weaken the interfaces and thus to isolate the 0° plies. Some panels were made with buffer strips of different width and spacings. The buffer strips arrested the cracks and increased the residual strengths significantly over those of plain laminates without buffer strips. A shear-lag type stress analysis correctly predicted the effects of layup, buffer materi al, buffer strip width and spacing, and the number of plies of buffer material.
Subject
Materials Chemistry,Mechanical Engineering,Mechanics of Materials,Ceramics and Composites
Cited by
20 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献