Bearing damage is one of the common failure modes in composite bolted joints. This paper describes the development of an on-site monitoring method based on eddy current (EC) sensing film to monitor the bearing damage in carbon fiber reinforced plastic (CFRP) single-lap bolted joints under tensile testing. Configuration design and operating principles of EC array sensing film are demonstrated. A series of numerical simulations are conducted to analyze the variation of EC when the bearing failure occurs around the bolt hole. The results of damage detection in the horizontal direction and through the thickness direction in the bolt hole with different exciting current directions are presented by the finite element method (FEM). Experiments are performed to prove the feasibility of the proposed EC array sensing film when the bearing failure occurs in CFRP single-lap bolted joints. The results of numerical simulations and experiments indicate that bearing failure can be detected according to the variation of EC in the test specimen.