Comparison of free thyroxine measurement by chemiluminescence and equilibrium dialysis following 131I therapy in hyperthyroid cats

Author:

Stammeleer Lisa1ORCID,Buresova Eva1,Stock Emmelie2,Feenstra Laurien3,Vandermeulen Eva2,Duchateau Luc4,Van de Maele Isabel1,Daminet Sylvie1

Affiliation:

1. Small Animal Department, Ghent University, Merelbeke, Belgium

2. Department of Medical Imaging of Domestic Animals, Ghent University, Merelbeke, Belgium

3. Department of Clinical Sciences of Companion Animals, Utrecht University, Utrecht, The Netherlands

4. Biometrics Research Group, Ghent University, Merelbeke, Belgium

Abstract

Objectives The first objective was to assess correlation between free thyroxine (fT4) measurements by equilibrium dialysis (fT4ED; Antech Diagnostics) and a chemiluminescent enzyme immunoassay (fT4CEIA; IMMULITE 2000 Veterinary Free T4 [Siemens Healthcare Diagnostics Products]) in hyperthyroid, otherwise healthy, cats before (T0), and 1 month (T1) and 11–23 months (T2) after radioactive iodine (131I) therapy. The second objective was to determine correlation between thyroid status based on fT4 (by both techniques) and the gold standard, thyroid scintigraphy. Methods Thyroid status, including thyroid-stimulating hormone (TSH), total thyroxine (TT4) and fT4 serum concentrations, were assessed in 45 client-owned hyperthyroid cats before (T0), and 1 month (T1) and 11–23 months (T2) after 131I therapy. fT4 was determined by a chemiluminescent enzyme immunoassay (CEIA) and equilibrium dialysis (ED). Quantitative thyroid scintigraphy (with sodium 99m-Tc-pertechnetate) was performed at T2. Results Spearman correlation between fT4CEIA and fT4ED was 0.81, 0.88 and 0.79 at T0, T1 and T2, respectively. fT4CEIA was consistently lower than fT4ED, with a median difference of −5.4 pmol/l ( P <0.001) and −4.9 pmol/l ( P <0.0001) at T1 and T2, respectively. At T2, all cats were identified as euthyroid based on thyroid scintigraphy. None of the cats were identified as being hypothyroid, based on serum TT4 and TSH measurements. Nine of 22 (40.9%) cats had an fT4CEIA below the reference interval (RI) at T2, whereas only 2/22 (9.1%) cats had an fT4ED concentration below the RI at T2. Conclusions and relevance Good correlation exists between both assays at T1 and T2, but a significant systematic difference is noted at both time points. This could be an indication for reconsideration of the current RI, although further studies are warranted for assessing test accuracy (in otherwise healthy cats and cats with non-thyroidal illness). At this time, routine use of fT4CEIA after 131I therapy is not advised in feline patients.

Funder

IDEXX Laboratories Inc

Publisher

SAGE Publications

Subject

Small Animals

Cited by 6 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3