Comparison of Resorbable Mesh (Poly L-Lactide/Glycolic Acid) and Porous Polyethylene in Orbital Floor Fractures in an Experimental Model

Author:

Aral Ali Mubin1ORCID,Özmen Selahattin2,Uygur Safak2,Kaya Basar3,Coskun Neslihan4,Ömeroglu Suna4,Kılıc Koray5

Affiliation:

1. Department of Plastic Surgery, Yenimahalle Research and Training Hospital, Yıldırım Beyazıt University, Ankara, Turkey

2. Department of Plastic Surgery, Koc University School of Medicine, İstanbul, Turkey

3. Department of Plastic Surgery, Ufuk University, Ankara, Turkey

4. Department of Histology/Embryology, Gazi University School of Medicine, Ankara, Turkey

5. Department of Radiology, Gazi University School of Medicine, Ankara, Turkey

Abstract

Background: Resorbable mesh and porous polyethylene are frequently used alloplastic materials for the treatment of the orbital blowout fractures. The literature lacks reports comparing their long-term effects on experimental models. Objective: Our aim was to radiologically and histologically evaluate the effectiveness and safety of porous polyethylene and resorbable mesh in a rabbit orbital blowout fracture model. Methods: Twelve New Zealand white rabbits (24 orbits) were randomized to 4 groups. In group 1, only orbital floor dissection was done. In group 2, following orbital floor dissection, a 10-mm defect was created without any extra procedure. In group 3, following a 10-mm defect creation, a 12-mm-round cut porous polyethylene was placed on the defect. In group 4, following a 10-mm defect creation, a 12-mm-round cut resorbable mesh was placed on the defect. Computed tomographic analysis was performed during follow-up period. Orbital floors were evaluated histologically at month 6. Results: No clinical complications were observed during follow-up period. In radiological evaluation, there was no statistically significant difference between groups regarding bone formation. In histological evaluation, the connective tissue was denser, and organized and better bone formation was observed in group 3 and 4 when compared with other groups. Conclusion: Although no significant radiological changes were present, porous polyethylene and resorbable mesh performed better histologically. They were effective and well tolerated for reconstruction of the isolated orbital floor defects.

Publisher

SAGE Publications

Subject

Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3