Affiliation:
1. Institute of Refrigeration and Cryogenics, Shanghai Jiao Tong University, Shanghai, People’s Republic of China
Abstract
Given current environment protection problems, improvement of energy utilization efficiency is a major focus of compressor research. Overflow, a method in which the high-pressure gas in the clearance volume is fully used, is introduced in the design of a swash plate compressor. The coefficient of performance (COP) of the swash plate compressor with overflow channel has a certain decrease compared with the conventional compressor, but the volumetric efficiency and the cooling capacity of a swash plate compressor with overflow channel are visibly more improved than those of a conventional compressor in terms of the same operation and dimension parameters. The overflow has beneficial effect on miniaturizing the swash plate compressor. The intake and exhaust times considerably improve after the overflow channel is incorporated into the swash plate compressor. This, in turn, substantially enhances cooling capacity of the theoretical results from 869 to 953 W, an improvement by about 10 per cent in this article; however, COP decreases by about 3.7 per cent.
Subject
Mechanical Engineering,Energy Engineering and Power Technology
Cited by
3 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献