Numerical analysis of the internal biased flow mechanism of the siphon outlet pipe under the action of axial flow pump

Author:

Yang Fan12ORCID,Sun Shengjie1,Jin Xiaoyu1,Li Sihai3,Xu Xudong4,Jin Yan1

Affiliation:

1. College of Hydraulic Science and Engineering, Yangzhou University, Yangzhou, China

2. Hydrodynamic Engineering Laboratory of Jiangsu Province, Yangzhou, China

3. Institude of Water Machinery and Municipal Research, Key Laboratory of Jinan Digital Twins and Intelligent Water Conservancy, Jinan, China

4. Institude of Material Sturcture, Water Resources Research Institude of Jiangsu Province, Nanjing, China

Abstract

One of the often employed flow structures in vertical pumping stations is the siphon outlet pipe. It has a complicated geometric structure and internal flow field, which directly affects how effectively, safely, and steadily pumping stations operate. The entire flow conduit of the vertical axial flow pump device was adopted as the study object in order to elucidate the mechanism of the internal biased flow of the siphon outlet pipe caused by the axial flow pump under different flow conditions, and the three-dimensional unsteady flow field of the vertical axial flow pump device was numerically solved using the numerical simulation technique. Physical model tests were used to confirm the results of the numerical simulation. The findings demonstrate that there is a horizontal bias in the flow of the inlet surface and outlet surface of the elbow pipe of the siphon outlet pipe, and that when the flow rate rises, the degree of the horizontal bias in the flow gradually diminishes, and the ratio of biased flow gradually decreases. The flow in hump segment presents up-and-down flow, and when the flow rate increases, the ratios of biased flow first rises before falling. The major causes of the production of biased flow in the outlet pipe are residual velocity circulation at the guide vane's outlet, wall constraint at the elbow pipe, and flow inertia; Under various flow conditions, the morphologies of the vortex structures in the outlet pipe vary; the characteristics of the energy conversion of each part of the pump device are disclosed, with the inlet pipe having the lowest proportion of energy conversion. Under the optimal flow condition, the elbow-inlet pipe's proportion of energy conversion is only around 1.04%, and the proportions of the guide vane, 60° elbow pipe, and siphon outlet pipe's energy conversion are significant and fluctuate with time. The proportion of energy conversion in the elbow-inlet pipe and siphon outlet pipe steadily increases as flow rate rises, but the proportion in the guide vane and 60° elbow pipe drops initially before increasing.

Funder

Technology Project of the Water Resources Department of Jiangsu Province

Open Research Fund of Key Laboratory of Jinan Digital Twins and Intelligent Water Conservancy

Science and Technology Plan Project of Yangzhou City

Scientific Research Program of Jiangsu Hydraulic Research Institute

Major Projects of the Natural Science Foundation of the Jiangsu Higher Education Institutions of China

National Natural Science Foundation of China

Postgraduate Research and Practice Innovation Program of Jiangsu Province

Publisher

SAGE Publications

Subject

Mechanical Engineering,Energy Engineering and Power Technology