Performance investigation on novel combined power generation and refrigeration system

Author:

Uma Maheswari G1,Ganesh N Shankar2ORCID,Srinivas Tangellapalli3,Reddy Bale Viswanadha4

Affiliation:

1. Department of Computer Applications, School of Information Technology and Engineering, Vellore Institute of Technology, Vellore, Tamil Nadu, India

2. Department of Mechanical Engineering, Kingston Engineering College, Vellore, Tamil Nadu, India

3. Department of Mechanical Engineering, Dr. B.R. Ambedkar National Institute of Technology, Jalandhar, Jalandhar, Punjab, India

4. Department of Mechanical and Manufacturing Engineering, Faculty of Engineering and Applied Science, Ontario Tech University (UOIT), Oshawa, ON, Canada

Abstract

This article aims to examine a novel combined power and refrigeration system, using renewable and waste heat sources suitable for low-temperature applications. The present system is an integrated Kalina cycle and ejector refrigeration system to generate power and refrigeration simultaneously. To improve the vapour generation, the separator vapour fraction is used as a decision variable. Relative irreversibility and efficiency defect as two important parameters considered in this system for an investigation to identify the weaker components. The combined system generates power and refrigeration with two different mediums by the incorporation of the heat exchanger at the turbine exhaust. The novel system's energy and conventional exergy evaluation are carried out through Python Software. The optimum values of decision variables: turbine concentration, separator vapour fraction, entrainment ratio, expander ratio, split ratio and turbine concentration are identified using Python software from an opted range of variables. The maximum value of net power output, first law efficiency for power generation system, combined system, second law efficiency for power generation system, combined system, refrigeration effect and coefficient of performance are obtained as 113 kW, 8.85%, 11.83%, 93.44%, 81.29%, 38.07% and 0.118, respectively, at higher separator vapour fraction. Among the components considered in the combined power generation system, the condenser and LTRGN account for the higher exergy destruction rate of 30.41% and 25.53%. The coefficient of performance is maximized at a higher value of the refrigeration effect. The turbine pressure at the inlet is increased with increments in turbine work on choosing the higher value of the expander ratio. The higher exergetic value components are not emphasized to focus on improvement.

Publisher

SAGE Publications

Subject

Energy (miscellaneous),Energy Engineering and Power Technology,Renewable Energy, Sustainability and the Environment,Environmental Engineering

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3