Hyperopia Correction Using an Erodible Mask Excimer Laser Delivery System Coupled to an Axicon: Preliminary Results

Author:

Brancato R.12,Carones F.1,Morico A.1,Venturi E.1,Vigo L.1,Spinelli A.1,Gobbi P.G.2

Affiliation:

1. Department of Ophthalmology and Visual Sciences, University of Milano, Milano - Italy

2. Laser Medicine Research, Scientific Institute San Raffaele Hospital, University of Milano, Milano - Italy

Abstract

Purpose. This paper presents the results of the first human trial on the correction of hyperopia using an erodible mask excimer laser delivery system coupled to an axicon. Methods. We treated 17 eyes of 17 patients (age range 34–62 years) for the correction of +3.21 ± 1.04 D (range +1.00 to +4.00 D). The hyperopic correction was made using an erodible mask inserted on the laser optical pathway, to produce a circular ablation measuring 6.5 mm in diameter. An axicon was then used to create a blend transition zone from 6.5 mm up to 9.4 mm in diameter. Eyes were evaluated at one, three and six months after surgery. Results. Reepithelization was always observed by the fifth postoperative day, despite the large area of deepithelization (diameter 9.5 mm). Mean refractive error one month after treatment was −2.44 ± 1.59 D (range 0.00 to −6.50 D). Five eyes (29.4%) had a best corrected visual acuity loss more than two to three lines; all eyes showed mild annular haze not involving the central part of the cornea. Six months after treatment, mean refractive error was −0.88 ± 0.99 D (range +0.50 to −3.00 D). Compared to preoperative status, 13 eyes (76.5%) showed an improvement in uncorrected distance visual acuity (1–8 lines), and 14 eyes (82.4%) showed an improvement in uncorrected vision at reading distance (3–7 lines). Two eyes (11.7%) showed a best corrected visual acuity loss of two of three lines. Conclusions. These preliminary results indicate this approach is effective in reducing hyperopia, while its predictability has still to be proved in a larger treatment group with longer follow-up. A cautious approach to this technique is still advisable, especially for higher hyperopic corrections, in view of the large best corrected visual acuity loss seen in two eyes at six months.

Publisher

SAGE Publications

Subject

Ophthalmology,General Medicine

Cited by 8 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Surgical Correction of Hyperopia;Survey of Ophthalmology;2006-07

2. Hyperopic Laser in situ Keratomileusis With 5.5-, 6.5-, and 7.0-mm Optical Zones;Journal of Refractive Surgery;2005-01

3. Mitomycin C and Surface Ablation;LASEK, PRK, and Excimer Laser Stromal Surface Ablation;2004-12-21

4. Scraping and Mitomycin C to Treat Haze and Regression After Photorefractive Keratectomy for Myopia;Journal of Refractive Surgery;2003-07

5. Photorefractive Keratectomy versus Laser In Situ Keratomileusis for the Treatment of Spherical Hyperopia1;Eye & Contact Lens: Science & Clinical Practice;2003-01

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3