Comparison of Internal Anterior Chamber Diameter Measured with Ultrabiomicroscopy with White-to-White Distance Measured Using Digital Photography in Aphakic Eyes

Author:

Wilczynski Michal1,Bartela Joanna1,Synder Aleksandra1,Omulecki Wojciech1

Affiliation:

1. Department of Ophthalmology, Medical University of Lodz, University Barlicki Hospital, Lodz - Poland

Abstract

Purpose Measuring the anterior chamber diameter (AC) is important both for diagnostics and before ocular surgery. In clinical practice, horizontal AC diameter is usually estimated on the basis of measurements of corneal diameter (so-called white-to-white [WTW] distance). The usual method for selecting an appropriate size for an AC lens is to add 1 mm to WTW measurement. The purpose of this study was to compare AC diameter measured using ultrasound biomicroscopy (UBM) with WTW distance measured using digital photography in aphakic eyes. Methods The data were gathered prospectively from a nonrandomized consecutive series of aphakic patients. The examined group consisted of 23 eyes of 23 adult patients, mean age 71.17 years. WTW diameter was measured in the 3 o'clock and 9 o'clock meridian on a digital photograph. Internal horizontal AC diameter measurements were performed in the 3 o'clock and 9 o'clock meridian with the Sonomed Ultrabiomicroscopy device with a 50-MHz probe. Results Mean horizontal WTW diameter measured using digital photographs was 11.65±0.38 mm and mean horizontal internal AC diameter measured using UBM was 13.53±0.83 mm. A significant difference in mean WTW diameter measured using digital photography and UBM was found (Mann-Whitney U test, p<0.05). There was a significant correlation between these values (Spearman=0.70, p<0.001). Conclusions In order to obtain good and precise measurements of internal AC diameter, a method of direct visualization of the intraocular structures should be used. Despite the limits of a small case series, our results support the use of UBM technique for preoperative evaluation of the internal AC diameter and AC intraocular lens sizing in aphakic eyes.

Publisher

SAGE Publications

Subject

Ophthalmology,General Medicine

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Pediatric Cataract Surgery in the Abnormal Anterior Segment;Pediatric Cataract Surgery and IOL Implantation;2020

2. Very High-frequency Digital Ultrasound Biomicroscopy;Ophthalmic Ultrasonography;2012