Screening for Glaucoma in a General Population with the Non-Mydriatic Fundus Camera and the Frequency Doubling Perimeter

Author:

Detry-Morel M.1,Zeyen T.2,Kestelyn P.3,Collignon J.4,Goethals M.2,

Affiliation:

1. St Luc University Hospital, Université Catholique de Louvain, Brussels

2. St Rafael University Hospital, KUL, Leuven

3. University Hospital, RUG, Gent

4. University Hospital, ULG, Liège - Belgium

Abstract

Purpose To evaluate the usefulness of non-mydriatic fundus camera (NMFu-camera) and frequency doubling perimeter (FDP) for detecting glaucoma in a general population. Methods This prospective observational multicenter study consisted in screening for glaucoma in the populations of three Belgian cities. Intraocular pressure (IOP) was measured with non-contact pneumo-tonometer (NCT) and applanation tonometry (AT) if NCT IOP was ≥17 mmHg. Visual field was screened with FDP (C-20-5) and digitized optic disc photographs (ODPs) were taken with NMFu-camera. FDP was considered abnormal if at least one defective point was found. ODPs were graded as normal or glaucomatous by consensus of three glaucoma specialists. Optic disc and visual field results were matched per eye. Subjects with known ocular hypertension and/or treated primary open angle glaucoma were excluded from the analysis. Results A total of 1620 subjects were included in the study. Their mean age was 63.2 years. AT IOP was >21 mmHg in 8.2%. A total of 98.1% of ODPs could be interpreted. Glaucomatous optic discs were detected in 3.5% of the subjects. In this group only 24% had an AT IOP ≥22 mmHg. FDP was abnormal in 44.5%. The sensitivity and specificity of FDP to identify patients with an optic disc graded as glaucomatous were 58.6% and 64.3% respectively. Conclusions The combined use of the NMFu-camera and the FDP is a feasible method for an initial glaucoma mass screening. NMFu-camera may be a useful and quick method to screen for glaucomatous damage in a community. FDP in screening strategy was revealed to be not sensitive enough when setting the cut-off value at one defective test location. IOP measurements were confirmed to be a poor tool to detect glaucomatous damage.

Publisher

SAGE Publications

Subject

Ophthalmology,General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3