Glare Disability in Patients with Hydrophilic and Hydrophobic Acrylic Intraocular Lens Implants

Author:

Akman A1,Bozbeyoglu S.1,Akova Y.A.1

Affiliation:

1. Başkent University Faculty of Medicine, Department of Ophthalmology, Ankara - Turkey

Abstract

Purpose To compare glare disability test results in patients with hydrophilic and hydrophobic acrylic intraocular lenses (IOL). METHODS Sixty eyes of 60 patients were studied in three groups of 20. Each eye in Group 1 had a single-piece hydrophilic acrylic (Bioacryl, Biotech, France) IOL implant, and each eye in Group 2 had a three-piece hydrophobic acrylic (AcrySof, Alcon, USA) IOL implant. Group 3 was the control group, and consisted of eyes without cataracts. Glare disability was tested using the Ophthimus glare sensitivity test (Ophthimus, Sweden). For each eye, we determined log contrast sensitivity values without exposure to glare source and with exposure to glare source. The difference between these values was recorded as the threshold contrast increase. An infrared camera was used to measure pupil diameter during glare disability testing, and pupil diameter greater than 4 mm was used as an exclusion criterion to eliminate edge design as a potential contributor to glare disability. Results The respective mean log contrast sensitivity scores for Groups 1, 2, and 3 in the absence of the glare source were 0.80±0.03, 0.81±0.04, and 0.79±0.08. The corresponding findings with glare source were 0.84±0.07, 0.89±0.07, and 0.84±0.03. The threshold contrast increase in Group 2 (0.070±0.035) was significantly higher than that in both Group 1 (0.043±0.040) and the control group (0.045±0.026) (p<0.05 for both comparisons). There were no significant differences between Group 1 and the control group regarding log contrast sensitivity values with glare source and threshold contrast increase (p>0.05 for both comparisons). CONCLUSIONS The eyes with hydrophilic acrylic IOL showed better glare disability results than those with hydrophobic acrylic IOL. The superior performance of the hydrophilic acrylic IOL could be related to their lower refractive index and equi-convex design.

Publisher

SAGE Publications

Subject

Ophthalmology,General Medicine

Cited by 5 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3