Cautery selection for oculofacial plastic surgery in patients with implantable electronic devices

Author:

Blandford Alexander D1,Wiggins Newton B2,Ansari Waseem1,Hwang Catherine J1,Wilkoff Bruce L2,Perry Julian D1

Affiliation:

1. Cole Eye Institute, Cleveland Clinic Foundation, Cleveland, OH, USA

2. Department of Cardiovascular Medicine, Cleveland Clinic Foundation, Cleveland, OH, USA

Abstract

Purpose: To discover oculofacial plastic surgeon practice patterns for cautery selection in the setting of implantable electronic devices and present guidelines based on a review of current literature. Methods: A 10-Question web-based survey was sent to the email list serve of the American Society of Ophthalmic Plastic and Reconstructive Surgery to determine surgeon cautery preference in the setting of various implantable electronic devices and comfort level with the guidelines for cautery selection in their practice or institution. The relationship between survey questions was assessed for statistical significance using Pearson’s Chi-square tests. Results: Two hundred ninety-three (41% response rate) surveys were completed and included for analysis. Greater than half of respondents either had no policy (36%) or were unaware of a policy (19%) in their practice or institution regarding cautery selection in patients with a cardiac implantable electronic device. Bipolar cautery was favored for use in patients with a cardiac implantable electronic device (79%–80%) and this number dropped in patients with implantable neurostimulators (30%). Overall, one-third of respondents did not feel comfortable with their practice/institution policy. Conclusion: Choices and comfort level among oculofacial plastic surgeons for cautery selection in patients with implantable electronic devices vary considerably, and some choices may increase the risk for interference-related complications. Practice patterns vary significantly in the setting of a neurostimulator or cochlear implant, where interference can cause thermal injury to the brain and implant damage, respectively. Guidelines are proposed for cautery selection in patients with implantable electronic devices undergoing oculofacial plastic surgery.

Publisher

SAGE Publications

Subject

Ophthalmology,General Medicine

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3