Anterior chamber aqueous flare is not a predictor for surgical closure of full-thickness idiopathic macular holes

Author:

Schaub Friederike1,Enders Philip1,Scholz Paula1,Müther Philipp S1,Fauser Sascha12,Kirchhof Bernd1

Affiliation:

1. Department of Ophthalmology, University of Cologne, Cologne, Germany

2. F. Hoffmann-La Roche AG, Basel, Switzerland

Abstract

Purpose: To investigate the predictive value of preoperative anterior chamber aqueous flare levels measured by laser flare photometry for surgical success of idiopathic macular holes in addition to preoperative anatomic characteristics. Methods: Records of 105 consecutive eyes with full-thickness idiopathic macular holes which underwent pars plana vitrectomy with internal limiting membrane peeling and sulfur hexafluoride 20% (SF620%) endotamponade were reviewed retrospectively. All patients underwent preoperative measurements of anterior chamber aqueous flare and anatomical idiopathic macular hole characteristics evaluated by optical coherence tomography: macular hole inner opening diameter, macular hole minimum linear diameter, macular hole base diameter, and macular hole height. Best-corrected visual acuity results were recorded pre- and postoperatively. Results: In 17 (16.2%) of 105 eyes primary closure of idiopathic macular hole failed, whereas in 88 eyes (83.8%) closure was achieved. Between both groups, preoperative macular hole minimum linear diameter (p = 0.001) and macular hole inner opening diameter (p = 0.006) were statistically different. Failure rates were significantly lower in eyes with macular hole minimum linear diameter < 400 µm (7.4% vs 32.4%; p = 0.013) and preoperative macular hole minimum linear diameter showed moderate correlation with pre- and postoperative best-corrected visual acuity results (r = 0.512; p < 0.001; r = 0.612; p < 0.001). Mean anterior chamber aqueous flare of 11.5 ± 9.9 pc/ms in eyes with anatomical closure and 11.8 ± 6.4 pc/ms in unclosed cases was comparable (p = 0.28) and did not correlate with anatomical or functional results. Conclusion: Eyes with idiopathic macular hole ⩾ 400 µm in size have a significantly higher failure rate following standardized pars plana vitrectomy with internal limiting membrane peeling and SF620% endotamponade. Preoperative macular hole minimum linear diameter and macular hole inner opening diameter seem to be associated with surgical outcome in idiopathic macular hole, whereas anterior chamber aqueous flare level does not provide additional predictive value.

Publisher

SAGE Publications

Subject

Ophthalmology,General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3