Affiliation:
1. Moorfields Eye Hospital, London, UK
Abstract
Background: Descemet’s membrane endothelial keratoplasty has a lower risk of endothelial rejection than Descemet’s stripping automated endothelial keratoplasty. In aphakic eyes requiring endothelial transplantation, approaches aimed at reducing the risk of posterior graft dislocation in Descemet’s stripping automated endothelial keratoplasty are not transferable to Descemet’s membrane endothelial keratoplasty. Technique: Here we describe the use of an implantable collamer lens placed over the iris to provide a temporary intraoperative platform, to facilitate graft unfolding and to avoid posterior graft dislocation in an aphakic, vitrectomised eye with a fixed, dilated pupil in a young patient with chronic uveitis and previous failed Descemet’s stripping automated endothelial keratoplasty.
Subject
Ophthalmology,General Medicine
Cited by
9 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献