Comparison of performance between two microcatheter systems in ab externo canaloplasty: A retrospective comparison study

Author:

Vastardis Iraklis1,Kontopoulou Kalliopi1,Fili Sofia1,Gatzioufas Zisis2,Kohlhaas Markus1

Affiliation:

1. Eye Clinic, St. Johannes-Hospital Dortmund, Dortmund, Germany

2. Eye Clinic, University Hospital Basel, Basel, Switzerland

Abstract

Purpose: To compare the performance of two different microcatheter systems, iTrack™ 250A and Glaucolight, in ab externo canaloplasty in three major categories: intraocular pressure reduction, drug therapy reintroduction, and evaluation of viscodilation over distension of the inner wall of Schlemm’s canal. Methods: A total of 56 and 46 eyes from different glaucoma types underwent ab externo canaloplasty using two different microcatheter systems. Group formation was made according to microcatheter system used. Kaplan–Meier test was performed for drug therapy reintroduction in relation to the two microcatheters. Tests of between-subject effects in two-way analysis of variance evaluated the efficacy of the two microcatheters and their features in relation to intraocular pressure reduction. Results: Kaplan–Meier test was not statistically significant (p = 0.20) regardless of microcatheter system. Tests of between-subject effects in relation to intraocular pressure reduction was not statistically different between the two microcatheters (p = 0.26) or between microcatheter and follow-up (p = 0.90). Intraocular pressure reduction in different glaucoma type was statistically significant during the follow-up period and glaucoma types showed different results between them in relation to follow-up (p < 0.001 and p = 0.002, respectively), but the pairwise comparison was not statistically important (p = 0.42). Intraocular pressure reduction was better in pseudophakic eyes in comparison with phakic eyes (p = 0.03), but the selection of microcatheter seemed not to affect this result (p = 0.11 and p = 0.32, respectively). Conclusion: Both microcatheter systems performed equal in terms of intraocular pressure reduction. Drug therapy reintroduction was not affected by the selection of the two microcatheters. Different types of glaucoma responded different to canaloplasty. Pseudophakic eyes responded better to treatment than phakic eyes, but the microcatheter selection seemed not affect this result.

Publisher

SAGE Publications

Subject

Ophthalmology,General Medicine

Cited by 6 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3