Orbital anatomy magnetic resonance imaging in diplopic versus non-diplopic patients after glaucoma drainage device placement

Author:

Shah Saumya M1ORCID,Kilgore Khin P1,Bothun Erick D1,Hunt Christopher H2,Khanna Cheryl L1ORCID

Affiliation:

1. Department of Ophthalmology, Mayo Clinic, Rochester, MN, USA

2. Department of Neuroradiology, Mayo Clinic, Rochester, MN, USA

Abstract

Purpose: New-onset persistent diplopia has become a common complication after glaucoma drainage device (GDD) placement. Understanding the orbital anatomy of such patients may provide information regarding risk of diplopia, GDD selection, and post-operative management. The purpose of this study was to examine the orbital anatomic differences in diplopic and non-diplopic patients after GDD implantation using high-resolution MRI. Methods: Seven eyes ( N = 4 with diplopia and N = 3 without diplopia after GDD placement) of seven patients that had undergone placement of Baerveldt 250 (B250), Baerveldt 350 (B350), or Ahmed FP7 (FP7) GDD were prospectively enrolled at a single institution. All patients underwent a 3.0T orbital MRI with 3D volumetric T1 and T2 weighted sequence. Images were analyzed for orbital volume, axial length, orbital distances, presence of superior rectus-lateral rectus (SR-LR) band, position of GDD, and SR-LR angles. Results: Patients with diplopia had smaller mean ± SD orbital axial (911.5 ± 111.8 mm3 vs 931.7 ± 79.7 mm3) and coronal volumes (1162.5 ± 145.5 mm3 vs 1180 ± 34.6 mm3) compared to non-diplopic patients. Average orbital rim distances were larger for the diplopic group. The SR-LR displacement angle for diplopic patients was larger (101.6° ± 8.1 vs 94.7° ± 17.6) while the SR-LR quadrantic angle (86.6° ± 4.2 vs 89.1° ± 4.3) was smaller. SR-LR band was present and intact in all patients. GDD malpositioning was not evident in any patient. Conclusion: The decreased orbital axial and coronal volumes as well as increased orbital rim distances in diplopic patients suggests the need for further studies to understand the role of orbital anatomy in occurrence of diplopia. Dynamic MRI imaging may be helpful in identifying differences in extraocular muscle function that reveal an etiology of diplopia in patients with GDD implantation.

Publisher

SAGE Publications

Subject

Ophthalmology,General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3