Comparison of incidence of repositioning surgery to correct misalignment with three toric intraocular lenses

Author:

Oshika Tetsuro1,Fujita Yoshifumi2,Hirota Atsushi3,Inamura Mikio4,Inoue Yasushi5,Miyata Kazunori6,Miyoshi Teruyuki7,Nakano Shinichiro8,Nishimura Tomohisa9,Sugita Toru10

Affiliation:

1. Department of Ophthalmology, Faculty of Medicine, University of Tsukuba, Ibaraki, Japan

2. Fujita Eye Clinic, Tokushima, Japan

3. Hirota Eye Clinic, Yamaguchi, Japan

4. Inamura Eye Clinic, Kanagawa, Japan

5. Inoue Eye Clinic, Okayama, Japan

6. Miyata Eye Hospital, Miyazaki, Japan

7. Miyoshi Eye Clinic, Hiroshima, Japan

8. Division of Ophthalmology, Ryugasaki Saiseikai Hospital, Ryugasaki, Ibaraki, Japan

9. Mikawa Eye Clinic, Saga, Japan

10. Sugita Eye Clinic, Tokyo, Japan

Abstract

Purpose: To compare the incidence of re-orientating surgery to improve misalignment of three models of acrylic toric intraocular lenses: AcrySof toric intraocular lens (Alcon Laboratories, Inc.), TECNIS toric intraocular lens (Johnson & Johnson Vision, Inc.) and HOYA 355 toric intraocular lens (HOYA). Methods: In this retrospective, multicenter case series, medical charts were reviewed for collecting data on realignment surgery of toric intraocular lenses at 10 ophthalmic surgical sites in Japan. Results: Over all, intraocular lens repositioning surgery was conducted in 89 of 9430 eyes (0.944%) at an average of 10.5 ± 9.7 days after the initial cataract surgery. The incidence was 0.213% (11/5155), 1.797% (62/3451) and 1.942% (16/824) with AcrySof, TECNIS and HOYA toric intraocular lenses, respectively. The incidence was significantly lower with AcrySof than with other two brands of toric intraocular lenses ( p < 0.0001). In those eyes which underwent reorientation surgery, the amount of misalignment was 26.4 ± 21.9°, 29.7 ± 15.4° and 28.1 ± 20.7° with AcrySof, TECNIS and HOYA toric intraocular lenses, respectively; there was no significant difference among groups ( p = 0.821). The repositioning surgery significantly reduced misalignment in all three groups. Conclusion: The rotational stability was considerably different among toric intraocular lenses of different manufacturers. The incidence of repositioning surgery was significantly lower with AcrySof than with TECNIS and HOYA toric intraocular lenses.

Publisher

SAGE Publications

Subject

Ophthalmology,General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3