Comparison of ultrasound energy consumption between low-energy femtosecond laser-assisted cataract surgery and conventional phacoemulsification cataract surgery in patients with different cataract densities

Author:

Ou YouCi1ORCID,Wang YuanShen1,Wu TzuEn12

Affiliation:

1. Department of Ophthalmology, Shin Kong Wu Ho-Su Memorial Hospital, Taipei

2. School of Medicine, Fu Jen Catholic University, New Taipei City

Abstract

Purpose Femtosecond laser-assisted cataract surgery (FLACS)'s effect on reducing ultrasound energy, accumulated with cumulative dispersed energy (CDE) units, still remains controversial. This study aims to evaluate the effect of low-energy FLACS on CDE with that of conventional phacoemulsification surgery (CPS) in different cataract densities from multiple surgeons. Methods It was a retrospective case–control study. Total 629 eyes receiving either low-energy FLACS (performed with Ziemer LDV Z8 platform) or CPS were divided into two groups according to preoperative grading of Lens Opacity Classification System III (LOCSIII): milder and harder cataract group. The mean CDE were compared in different cataract densities and surgeons. A linear regression analysis was performed to evaluate the effect of using low-energy FLACS on CDE in harder cataract cases. Results We found overall CDE had no significant difference between two surgeries. However, low-energy FLACS led to a significantly lower CDE in patients with harder cataracts than CPS (18.47 ± 4.32 vs. 12.96 ± 2.34; p < 0.001). Similar results were observed in the three surgeon subgroups and in linear regression analysis and no significant difference of the effect accounting for surgeons. Moreover, low-energy FLACS results in a reduction of energy consumption comparing to CPS and has endothelial sparring effect in patients with harder cataracts. Conclusions The reduced energy consumption was observed by using low-energy FLACS irrespective of surgeons’ experience or the approaches adopted in patients with harder cataracts. Therefore, we can have more confidence to suggest this innovative platform to the patients in such cases.

Publisher

SAGE Publications

Subject

Ophthalmology,General Medicine

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3