Characterization of the effect of intracorneal ring segment in corneal ectasia after laser refractive surgery

Author:

Peris-Martínez Cristina12,Bueno-Gimeno Inmaculada3,Alvarez-Arana Izaskun3,Piñero David P4,Gené-Sampedro Andrés35

Affiliation:

1. FISABIO Oftalmología Médica (FOM), Cornea and External Diseases Unit, Valencia, Spain

2. Aviño&Peris Eye Clinic, Valencia, Spain

3. Department of Optics and Optometry and Vision Sciences, University of Valencia, Valencia, Spain

4. Department of Optics, Pharmacology and Anatomy, University of Alicante, Alicante, Spain

5. Research Institute on Traffic and Road Safety (INTRAS) University of Valencia, Valencia, Spain

Abstract

Purpose: To evaluate the visual, refractive, topographic, pachymetric, and biomechanical outcomes after intracorneal ring segment implantation in corneas with post-LASIK ectasia. Methods: Retrospective longitudinal study enrolling 26 eyes of 22 patients with post-LASIK ectasia and undergoing intracorneal ring segment implantation (KeraRing®, Mediphacos) using a 60-kHz femtosecond laser (IntraLase®, IntraLase Corp.) for corneal tunnelization. Visual, refractive, anterior, and posterior corneal topographic (Pentacam HR, Oculus), pachymetric, and corneal biomechanical changes (Ocular response Analyzer, Reichert) were evaluated during a 12-month follow-up. Vector analysis of astigmatic changes was performed. Results: A statistically significant reduction of sphere (p = 0.043) was observed at 1 month after surgery, with a significant improvement of uncorrected distance visual acuity associated (p = 0.019). Likewise, a significant reduction of anterior corneal power measurements (p ⩽ 0.014) and steepest posterior keratometric reading (p = 0.006) were observed at 1 month postoperatively, with no significant changes afterwards (p ⩾ 0.133). No significant changes were observed in manifest cylinder (p ⩾ 0.175), corrected distance visual acuity (p ⩾ 0.174), flattest posterior keratometric measurement (p ⩾ 0.282), volumetric measurements (p ⩾ 0.051), and corneal biomechanical parameters (p ⩾ 0.068). Vector analysis revealed an initial trend to overcorrection of astigmatism, with a trend to undercorrection at the end of follow-up and a significant variability in the outcome achieved in each patient. Conclusion: The implantation of KeraRing segments in post-LASIK corneal ectasia generates a significant modification of spherical refraction and a visual improvement due to a central corneal flattening generated. More refined nomograms of implantation in these cases should be developed to achieve a more predictable correction of astigmatism.

Publisher

SAGE Publications

Subject

Ophthalmology,General Medicine

Cited by 5 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3