Abstract

Purpose To compare the accuracy of Sirius ray tracing software with the Barrett Universal II formula for intraocular lens power prediction in virgin eyes. Methods Retrospective case series including 86 eyes that have undergone uneventful cataract surgery with SN60WF implantation. The median absolute error, mean prediction error, variance, and the percentage of eyes within ± 0.25 D, ± 0.50 D, ± 0.75 D, and ± 1.00 D of the prediction error in refraction were calculated. The correlation of prediction error with different baseline parameters was investigated. Results No differences were found between the median absolute error of the Barrett Universal II formula (0.226 D) and the ray tracing software with different intraocular lens centerings; apex (0.331 D), limbus (0.345 D), and pupil (0.342 D) ( p = 0.084). The variance, from lowest to highest, was the Barrett Universal II (0.144 D2), ray tracing-limbus (0.285 D2), ray tracing-pupil (0.285 D2), and ray tracing-apex (0.287 D2) ( p = 0.027). The Barrett Universal II formula showed a higher percentage of eyes within ± 0.25 D (56.98%), ± 0.50 D (82.56%), and ± 0.75 D (93.02%) compared to ray tracing software ( p < 0.01). A significant correlation between the prediction error of the Barrett Universal II formula and corneal diameter (r = 0.322, p = 0.002) and pupil diameter (r = 0.230, p = 0.033) was found. Also, a positive correlation between the prediction error of Sirius ray tracing and axial length ( p < 0.001) and pupil diameter ( p = 0.01) was found. Conclusion There is a trend of the Barrett Universal II formula to be more accurate than Sirius ray tracing software for intraocular lens power calculation in virgin eyes. This should be confirmed in future prospective comparative studies.

Publisher

SAGE Publications

Subject

Ophthalmology,General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3