Affiliation:
1. Unit of Macula. Department of Ophthalmology, Hospital de La Ribera, Alzira, Valencia, Spain
Abstract
Purpose To show an alternative surgical technique for the introduction of the intravitreal fluocinolone acetonide (FAc) implant (Iluvien®) into the vitreous cavity using a 23-gauge (G) trocar if it is retained during its implantation in the subconjunctival space. Methods We describe the surgical procedure performed to solve the complication: The FAc implant was extracted from the subconjunctival space using flat retinal forceps. A 23-G trocar was inserted 3,5 mm to the limbus. The same flat retinal forceps were used to take the FAc implant and introduce it into the vitreous cavity using a 23-G trocar. Results The patient's best corrected visual acuity (BCVA) (Snellen) improved from 20/200 to 20/63 and the central macular thickness (CMT) was reduced from 610 microns (µm) to 215 µm after one week of the FAc implantation. He remained stable after 3 months of follow-up, with a BCVA of 20/63 and a CMT of 191 µm. His intraocular pressure (IOP) remained stable and the integrity of the implant was checked by indirect ophthalmoscopy. Conclusion The introduction of the intravitreal FAc implant using a 23-gauge trocar constitutes a valid alternative if it is retained during its implantation in the subconjunctival space. The functionality of the implant remained intact in our patient.
Subject
Ophthalmology,General Medicine
Cited by
1 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献