Spontaneous Extrusion of a Stainless Steel Glaucoma Drainage Implant (Ex-PRESS)

Author:

Tavolato M.1,Babighian S.1,Galan A.1

Affiliation:

1. Department of Ophthalmology, Sant'Antonio Hospital, Padova - Italy

Abstract

Purpose To report a case of spontaneous extrusion of a stainless steel glaucoma drainage implant (Ex-PRESS). Methods An Ex-PRESS was implanted under the conjunctiva in a 76-year-old man with primary open-angle glaucoma. Results Two years after implantation, the Ex-PRESS extruded spontaneously. Despite this adverse event, there was no increase in intraocular pressure. Conclusions This is the first report of spontaneous extrusion of an Ex-PRESS device. Implanting the device under a scleral flap should be considered to avoid adverse events such as extrusion or conjunctival erosion.