Retinal microvascular density modifications during the water drinking test

Author:

Gameiro Gustavo Rosa1ORCID,Gameiro Giovana Rosa23ORCID,Farah Michel Eid1,Wang Jianhua3,Schor Paulo1

Affiliation:

1. Department of Ophthalmology and Visual Sciences, Paulista School of Medicine, Federal University of Sao Paulo – EPM/UNIFESP, São Paulo, São Paulo, Brazil

2. Health Sciences Center, State University of Londrina, Londrina, Parana, Brazil

3. Department of Ophthalmology, Bascom Palmer Eye Institute, University of Miami, Miami, FL, USA

Abstract

Purpose: The water drinking test (WDT) is a well-known stress test that increases intraocular pressure (IOP) momentarily and can indicate risk of glaucoma progression. This study focuses on correlating changes in the retinal microvascular plexus with the WDT in young healthy subjects. Methods: A total of 20 eyes of 20 healthy young subjects (mean age 24.37 ± 2.17 years) were included in this study. In our protocol, WDT consisted of drinking 1 L of water within 5 min. Outcome measures in this prospective observational study were mean arterial pressure (MAP), heart rate (HR), IOP, and retinal vessel density of both superficial and deep macular retina using optical coherence tomography angiography (OCTA), which were assessed before water ingestion and four times after at 15-min intervals. OCTA images were later quantified by fractal analysis (box counting [ Dbox]). One-way repeated measures analysis of variance (ANOVA) was used to assess the effects of WDT on each of the parameters. Results: The WDT resulted in significant peak changes of the following parameters compared to baseline: IOP: 15.63 ± 3.37 versus 18.38 ± 4.53 mmHg at 30 min, p < 0.001; HR: 75.74 ± 12.23 versus 64.95 ± 11.37 bpm at 15 min, p < 0.001; deep retinal vessel density 1.758 ± 0.14 versus 1.749 ± 0.16 at 15 min, p = 0.040. Conclusions: Besides IOP elevation and systemic effects in HR, WDT is associated with temporary modifications of the deep vascular plexus in young healthy subjects.

Publisher

SAGE Publications

Subject

Ophthalmology,General Medicine

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3